NEC 404.4 · Homes and commercial

Switches in wet locations and near tubs

Switches in damp or wet locations need a weatherproof enclosure or cover. No switch may be installed inside a tub or shower space unless it is part of a listed tub or shower assembly.

What the code requires

A surface-mounted switch or circuit breaker in a damp or wet location must be in a weatherproof enclosure or cabinet that meets 312.2. A flush-mounted switch or breaker in those locations needs a weatherproof cover.

Switches may not be installed within tub or shower spaces unless they are part of a listed tub or shower assembly.

On the job

  • Standard switch plates on exterior walls or patios are a common correction; switches there need weatherproof covers.
  • A switch installed within the tub or shower space itself, unless it is part of a listed tub or shower assembly, is another correction.

In California

California's 2025 code adds a rule for OSHPD-regulated health facilities only: no switches within 3 ft of tub or shower perimeters, with exceptions for nurse-call devices. It does not apply to homes or ordinary commercial buildings.

Related sections

Where this comes from

0/300

Answers come from this library only and are written by AI. They can be wrong, so check the cited section and confirm with your building department.

San Clemente · South OC to North County San Diego

Send a photo. Get a real answer.

Text is fastest, and a photo quote is free. Call if it is urgent, if you smell something burning, or if a breaker will not reset.

CSLB #354550 · C-10 Electrical · Licensed since 1978 · $25,000 contractor's bond