NEC 230.70 · Homes and commercial

Where the main service disconnect must go

A building supplied by a service needs a means to disconnect all of its hot conductors from the service conductors. It must be readily accessible, outside or inside nearest where the service conductors enter, never in a bathroom, and marked as a service disconnect.

What the code requires

The code requires a means to disconnect all ungrounded conductors in a building from the service conductors.

Under 230.70(A)(1), the disconnect must be readily accessible and either outside the building or inside, nearest the point where the service conductors enter. Under 230.6, conductors count as outside the building in several cases, for example under at least 2 in. of concrete beneath the building.

The disconnect may not be in a bathroom. If remote-control devices operate it, the disconnect itself must still meet the location rule. Each service disconnect must be permanently marked as a service disconnect, and it must be suitable for the conditions where it is installed, including hazardous locations.

On the job

  • A main panel placed deep inside the house, far from where the service conductors enter, is a common correction.
  • A panel installed in a bathroom is not allowed.
  • A missing service disconnect marking.
  • Proposals in the 2026 NEC revision cycle move one- and two-family service disconnects outdoors. California has not adopted that edition, so the 2023 rule on this page applies.

Related sections

Where this comes from

0/300

Answers come from this library only and are written by AI. They can be wrong, so check the cited section and confirm with your building department.

San Clemente · South OC to North County San Diego

Send a photo. Get a real answer.

Text is fastest, and a photo quote is free. Call if it is urgent, if you smell something burning, or if a breaker will not reset.

CSLB #354550 · C-10 Electrical · Licensed since 1978 · $25,000 contractor's bond